ARGES Nitrate Sensor

The ARGES Nitrate Sensor by Keynes Controls, is a submersible sensor that has been designed to simplify the acquisition of water quality measurement parameters into any platform that supports real-time reporting, data logging operations.

The Intelligent Submersible Nitrate Sensor measures the charged nitrate ions in the water.

The ARGES Nitrate sensor can be used stand-alone, or be installed into a ARGES Multiparameter SONDE.

The ARGES Nitrate Sensor by Keynes Controls directly supports SDI12, RS485 and MODBUS digital networks.

ARGES Nitrate sensor fitted multi-parameter SONDE
Submersible ARGEs Nitrate Sensor

Measurement Integrity

All of the ARGEs sensor range have the serial number and the last calibration date stored internally. The user can access this information for reporting purposes. The sensors can be redeployed at any time with the calibration and serial number records are retained in the sensor.

Product Features

TYPE RANGE (Typical levels)  
Solid state ISE sensor.
Measurement range: 1.0 - 62000 mg/L /  1x10-5  to 1x10-1 Mol  / 1 to 62000 ppm - Auto-ranging
Nitrate Resolution: 0.01 ppm
Nitrate Accuracy: +/- 10% of Reading
Built-in Digital Networks
SDI12 / RS485 / MODBUS  (16 & 32 Bit Registers)
Sensor life: Re-calibrate after 5000 hours (3 months)
pH Range 2-11
Isolated Electrodes Between measurements / standby mode.
Sensor Element Solid State
Interference IONS CIO4-, CIO5-,I-, CN-, BF4-
SI Units ppm Degree Celsius

ISOLATION

The sensor element of the Nitrate Sensor is isolated when not required to make a measurements. This reduces contamination of the sensor element and maintains the long active life of the device.

When no measurement is being made the sensor is in low power mode.

Calibration Summary

Keynes Controls offer a calibration kit for The Intelligent Submersible Nitrate Sensor and this is available from the online store.

The ARGES Nitrate Sensor is typically calibrated at 2 points. A zero point which uses distilled water, and the high end calibration point using one of the calibration standard solutions.

The overall accuracy of the sensor will depend upon how well the sensor is calibrated. For optimum results calibrate the sensor at the same temperature of the solution under test.

The QLOG applications software gives the user the ability to write calibration settings into the sensor.

 

ARGES Nitrate sensor
ARGES Nitrate sensor calibration

Storage and Handling

When not in use the ARGES Nitrate Sensor by Keynes Controls can be stored dry for a long period of time without any degradation in performance. Should the sensor not be used for a considerable length of time then soak the sensor in a low Nitrate concentration solution for several hours before use.

Storage temperature range : -2 to 60 Degrees Celsius.

Further Information

The majority of nitrate in groundwater in the UK is derived from diffuse pollution from agriculture, with the rest from sewage sludge disposal to land, atmospheric deposition and point sources.

Nitrate levels in our water resources have increased in many areas due to applications of inorganic fertiliser and animal manure in agricultural areas. The regulatory limit for nitrate in public drinking water supplies was set to protect against infant methemoglobinemia, but other health effects have not been considered.

Application Uses

  • Natural water
  • Surface Water
  • Ground water
  • Produced Water
  • Water Purification

     Monitoring applications.

Product Specifications

DISSOLVED Nitrate ENVIRONMENTAL CHARACTERISTICS
Range 1 - 62000 ppm Storage Range: -6 to 55 Degree Celsius
Resolution 0.01 ppm Ambient Range: 0 - 50    Degree Celsius
Accuracy 10 % Reading Water Temperature:     1 to 40  Degree Celsius
Maximum Depth: 50 m
Process Electrodes:    Solid State
PHYSICAL DIMENSIONS
Length x Diameter: 22 x  220 mm
Weight: 97 g
Settling Time
Typically 30 Seconds
 
Wiper Trigger SDI12 Command  aM!
Built-in Network Types:
Excitation Potentiometric SDI12 / RS485 / MODBUS over 485
Housing PVC / Stainless steel 316
Sensor Connector Gold Plated Power Requirement
Voltage Range: 10-18 V DC
Data Output - PPM Deg C Standby Current: 0.9 mA    Typical
Reading: 25 mA for 1 Sec - Typical


Please Note: The ARGES Nitrate sensor is pre-calibrated at the factory.

Supported Commands

Most Used Commands - SDI12

Description Master        Instrument Response
Start measurement aM! a05\r\n    where 05 = time delay before measurement sent
Send ID al! a14KEYNESCOISO000014\r\n    Part description assigned by Keynes
Address Query ?! Where a = ID number - 0 - 9 (standard) / (a..z) Enhanced SDI-12
0 - 9 / a - z for RS485
Change Address aAb!  where a = Initial address  and  b = Final address
Start Measurement aM! Make a measurement  - a = address of sensor
Example   1M! starts a measurement for sensor with ID=1
Concurrent measurement:
Used for starting a measurement
for all the sensors in a SONDE or
on a digital network.
aC! Start a measurement for sensor on address 'a'.
Read Serial Number aXSN! Instrument Response    a+Serial-number
Calibration Date aXCD! Instrument Response     a+date

Commonly used with: Ammonia, pH, Tryptophan CDOM Sensors. 

The Submersible ARGES Nitrate Sensor by Keynes Controls monitors the amount of charges nitrate ions in water. The ARGES Nitrate Sensor readings can be affected by changes in temperature and ionic activity. This sensor is frequently paired with CDOM, pH, and other chemical sensors crafted and produced by Keynes Controls.

Submersible pH Sensor = The Intelligent Submersible pH Sensor by Keynes Controls, is a high performance submersible sensor that has been designed to simplify the acquisition of water quality measurement parameters into any platform that supports data logging operations using digital network communications. Read More...

Built-in Communication Options

The ARGES Nitrate Sensor supports SDI12, RS485 and MODBUS digital communications as standard enabling it to be directly connected to Data Logger for remote web based reporting, onto Wi-Fi and Local Area Networks using the RS485 option. The MODBUS and RS485 option are often used to connect sensors to a PLC Controller and Display Units,. The MODBUS protocol enables the sensors to be used directly by most SCADA applications software.

ARGES Submersible Nitrate sensor built-in communications

Multiparameter Housing

Multiparameter ARGES kit prepared for deployment

The ARGES Nitrate Sensor by Keynes Controls can be used as a stand-alone device or as a part of a multi-parameter solution. Keynes Controls currently manufacture 7 port and 3 port sensor housings. An optional brush unit can be installed to clean the fluorometer optics.

Only a single network connection fitted to the base of the housing is required to communicate with all the internal sensors. The internal sensors will automatically detect the network traffic and start operations.

The ARGES Nitrate sensor is integrated into the Keynes Controls Q-LOG software.

Our Q-LOG software runs on the widely recognised Windows Operating system, you have the ability to calibrate, adjust instrument network address, and effortlessly display measurements on a series of panel meters and charts. Conveniently store results in text based files for quick analysis in spreadsheets.

 

Real Results Nitrate, Conductivity and Chloride
Additional Information:
Related Products by Keynes Controls: ARGES pH, ARGES Tryptophan, ARGES Conductivity, ARGES Nitrate, ARGES Turbidity, ARGES Hydrocarbon, ARGES CDOM, Dissolved Oxygen, ARGES Chloride, MODBUS, SDI12,RS485 , USB-SDI12-Pro, USB-485-Pro, QLOG
Key Words Related to Identifying Our Products or Intended Product Use or Product Outcome: Water, H2O, Water Disinfection, Water Sterilization, Lead, Potassium, Nitrate, SONDE, Water Quality, Turbidity, Water Quality Testing, Clean water, Multi-parameter water